Buckling Eigenmodes of a Column

The illustrated structure was analyzed by Rubin and Aminbagai (Stahlbau (1997), Issue 5).

 

Case 1:

EI1 = 15,000 kNm², EI2 = 20,000 kNm²

Ha = 3 kN, Va = 200 kN,
Hb = 2 kN, Vb = 300 kN,
P = 400 kN

 

Case 2:

EI1 = EI2 = 15,000 kNm²

Ha = 3 kN, Va = 0 kN,
Hb = 2 kN, Vb = 0 kN,
P = 400 kN

The stability analysis delivers, in complete agreement with the above
publication, the following buckling eigenmodes and results:

Case 1 Case 2
Buckling load factor = 2.14

Buckling lengths:

sk1=7.724m
sk2=8.425m

Buckling load factor = 3.58

Buckling lengths:

sk1=6.559m